13. janvāra iela 3, Rīga

Technical Overview

At VerdantVault, we've engineered our colocation facility to meet the demanding requirements of modern IT infrastructure while maintaining our commitment to sustainability. Our technology stack incorporates industry-leading solutions across physical infrastructure, power, cooling, networking, and security systems.

This page provides technical details that influence your colocation decisions, helping you understand the capabilities, reliability measures, and specifications of our facility. Whether you're considering a quarter rack or a private cage, these technical foundations ensure your equipment operates in an optimal environment.

Data center rack layout with efficient organization

Physical Infrastructure

Facility Layout

Our 2,500 square meter facility is strategically divided into security zones with dedicated areas for different colocation options:

  • Shared Cabinet Zone: Area for quarter and half-rack clients with shared security but individual locking mechanisms
  • Full Rack Zone: Dedicated area for full cabinet deployments with row-level security
  • Private Cage Area: Separated section for secure cage deployments with additional security layers
  • Meet-Me-Room (MMR): Carrier-neutral interconnection facility with restricted access
  • Loading Bay: Secure equipment receiving area with dedicated path to colocation floor

Rack Options & Specifications

We offer standardized rack solutions to ensure compatibility and optimal space utilization:

Quarter Rack Allocation

  • 10U of dedicated space in a shared 42U cabinet
  • Individual locking door for your section
  • Dedicated PDU outlets with remote monitoring
  • Standard 19" mounting rails with square holes

Half Rack Allocation

  • 21U of dedicated space in a shared 42U cabinet
  • Individual locking door for your section
  • Dedicated PDU with outlet-level monitoring
  • Adjustable mounting rails with cable management options

Full Rack

  • Complete 42U cabinet for your exclusive use
  • Biometric or combination lock options
  • Dual PDUs with outlet-level switching capabilities
  • 600mm or 800mm width options with various depth configurations
  • Advanced cable management systems included

Private Cage

  • Custom-designed secure area with minimum 100 sq ft
  • Dedicated biometric access control at cage entrance
  • Dedicated CCTV coverage of cage perimeter and interior
  • Option for customer-provided locks in addition to facility security
  • Flexible expansion capabilities as your needs grow

Mounting & Cabling Standards

Mounting Standards

  • Rail Type: EIA-310 compliant 19" square hole rails
  • Weight Capacity: Up to 1,500kg per rack (3,300 lbs)
  • Rail Adjustability: Front-to-back adjustable mounting depths
  • U Markings: Clear unit markings on all rails
  • Mounting Hardware: Cage nuts and screws provided

Cabling Standards

  • Copper: Cat6A standard for all in-rack copper cabling
  • Fiber: OM4 multimode and OS2 single-mode supported
  • Pathways: Overhead cable trays with fiber/copper separation
  • Labeling: Comprehensive cable labeling system at both ends
  • Management: Vertical and horizontal cable management included

Power Infrastructure

Power Redundancy Topology

Our facility implements a comprehensive power redundancy strategy to ensure continuous operation:

N+1 Configuration (Standard)

  • UPS Systems: Multiple parallel UPS units with N+1 redundancy
  • Generators: N+1 diesel generator configuration
  • Power Paths: Dual power feeds to racks with automatic transfer switches
  • Runtime: 10 minutes UPS backup at full load, 72+ hours generator operation

2N Configuration (Premium Option)

  • UPS Systems: Fully independent A+B power systems
  • Generators: Separate A+B generator banks
  • Power Paths: Completely isolated A+B distribution paths
  • PDUs: Separate A+B rack PDUs for dual-corded equipment

Per-Rack Power Provision

Rack Type Standard Power Maximum Available Voltage/Phase Circuit Protection
Quarter Rack 1.5kW (6.8A) 2.5kW (11.4A) 230V/1-phase 16A breaker
Half Rack 3kW (13.6A) 5kW (22.7A) 230V/1-phase 32A breaker
Full Rack 6kW (27.3A) 12kW (54.6A) 230V/1-phase 63A breaker
Full Rack (HPC) 12kW (17.3A) 20kW (28.9A) 400V/3-phase 32A 3-phase breaker
Private Cage Custom Up to 30kW per rack 230V/1-phase or 400V/3-phase Custom configuration

PDU Options

Basic Monitored PDUs

  • Total load monitoring
  • Threshold alerting
  • Network accessible
  • Historical usage data

Advanced Switched PDUs

  • Outlet-level switching
  • Per-outlet monitoring
  • Scheduled power cycling
  • Secure outlet groups
Advanced power and cooling infrastructure

Remote Power Management

All racks include remote power management capabilities, allowing you to:

  • Monitor: Real-time power consumption metrics
  • Reboot: Remote power cycling of equipment (switched PDUs)
  • Analyze: Historical power usage trends and reports
  • Alert: Power threshold notifications
  • Calculate: Power efficiency metrics

Cooling & Environmental Controls

Hot and cold aisle containment with advanced cooling systems

Cooling Infrastructure

Our cooling infrastructure implements best practices for efficiency and reliability:

CRAC Units

  • Type: Precision Computer Room Air Conditioning units
  • Redundancy: N+1 configuration for continuous operation
  • Capacity: Total cooling capacity exceeds 150% of maximum IT load
  • Efficiency: Variable speed fans and compressors for energy optimization

Hot/Cold Aisle Containment

All colocation areas implement strict containment strategies to maximize cooling efficiency:

  • Containment Type: Cold aisle containment with sealed cabinet rows
  • Cold Aisle Temperature: Maintained at 21-24°C (70-75°F)
  • Hot Aisle Temperature: Typically 35-40°C (95-104°F)
  • Humidity Control: Maintained between 40-60% relative humidity
  • Airflow Management: Floor grilles with adjustable dampers for precise air distribution

Environmental Sensors

Our facility is equipped with a comprehensive network of environmental sensors:

Temperature Monitoring

  • Coverage: Every cold and hot aisle
  • Vertical Profiling: Top, middle, bottom of racks
  • Logging: 5-minute interval data collection
  • Alerts: Immediate notification of threshold violations

Additional Environmental Monitoring

  • Humidity: Relative humidity sensors throughout facility
  • Airflow: Differential pressure sensors for containment integrity
  • Leak Detection: Under-floor water detection cables
  • Air Quality: Particulate and contaminant monitoring

Per-Cage Environmental Monitoring

Private cage clients receive dedicated environmental monitoring:

  • Custom Sensors: Additional temperature/humidity sensors within your cage
  • Dashboard: Real-time web portal for environmental conditions
  • Historical Data: 12-month retention of environmental metrics
  • Custom Thresholds: Client-defined alerting parameters

Network & Connectivity

Carrier Neutrality

Our facility maintains true carrier neutrality, giving you complete freedom to choose connectivity providers that best meet your requirements. We currently host multiple global and regional carriers, providing diverse options for bandwidth, latency, and cost optimization.

Meet-Me-Room Description

Our purpose-built Meet-Me-Room (MMR) serves as the central connectivity hub of the facility:

  • Security: Dedicated access control separate from colocation floor
  • Diverse Paths: Multiple building entry points for carrier redundancy
  • Patch Panels: Centralized fiber distribution frames
  • Cross-Connect Types: Fiber (single-mode, multi-mode) and copper options
  • Scalability: Designed with capacity for additional carrier expansion

Cross-Connect Options

Media Type Connector Types Typical Applications Lead Time
Single-mode Fiber LC, SC Carrier connections, long-distance links 24-48 hours
Multi-mode Fiber LC, SC, MPO Inter-cage connections, short-distance high-bandwidth 24-48 hours
Cat6A Copper RJ45 Management networks, low-bandwidth connections 24 hours
Coaxial BNC, F-type Specialized applications, legacy systems 48-72 hours
Fiber cross-connect infrastructure in the meet-me-room

Supported Port Types

Standard Ports

  • 1GbE: 1000BASE-T, 1000BASE-SX/LX
  • 10GbE: 10GBASE-SR/LR/ER, 10GBASE-T
  • 25GbE: 25GBASE-SR/LR

High-Speed Ports

  • 40GbE: 40GBASE-SR4/LR4
  • 100GbE: 100GBASE-SR4/LR4/CWDM4
  • 400GbE: Available on request

Cross-Connect Process

  1. Request: Submit cross-connect request via customer portal or support ticket
  2. Approval: Carrier/destination party approves connection request
  3. Scheduling: Installation time scheduled with typical 24-48 hour lead time
  4. Implementation: Cross-connect physically installed and tested by our technicians
  5. Notification: Both parties notified upon completion with test results
  6. Billing: Monthly recurring cross-connect fee applied to your account

Access Control & Security

Biometric access control system with multi-factor authentication

Biometric Authentication Details

Our multi-layered biometric system provides enterprise-grade physical security:

  • Primary Biometric: Fingerprint recognition with liveness detection
  • Secondary Biometric: Iris scanning for high-security areas (optional)
  • Access Cards: HID iCLASS SE cards with encrypted communication
  • Mobile Access: Smartphone-based authentication option
  • PIN Codes: Numeric codes as additional authentication factor

Multi-factor Physical Access Flow

Our comprehensive security process includes:

  1. Perimeter Security: Secured building entrance with guard verification
  2. Reception Check-in: ID verification against authorized access list
  3. Access Card Activation: Temporary or permanent credentials issued
  4. Mantrap Entry: Interlocking doors prevent tailgating
  5. Biometric Verification: Fingerprint/iris scan confirmation
  6. Data Center Floor Access: Final authorization point
  7. Cage/Rack Access: Individual authorization for specific customer equipment

Visitor Logging

All facility access is meticulously tracked and logged:

  • Pre-registration: All visitors must be registered at least 24 hours in advance
  • ID Verification: Government-issued photo ID required and scanned
  • Authorization Check: Verification against approved access list
  • Timestamp Logging: Entry and exit times recorded
  • Video Correlation: Access events linked to CCTV footage
  • Audit Trail: Complete visitor logs maintained for 12 months

Mantrap Description

Our security mantrap system prevents unauthorized access through tailgating:

  • Configuration: Interlocking doors with weight-sensitive floor
  • Single-person Detection: Weight sensors and optical systems
  • Monitoring: 24/7 security camera coverage inside mantrap
  • Alarm Integration: Immediate alert if tailgating detected
  • Emergency Features: Fire safety overrides and emergency release

CCTV Specifications

Camera Systems

  • Camera Type: IP-based HD cameras (minimum 4MP resolution)
  • Frame Rate: 30fps with motion-triggered high-frame-rate mode
  • Coverage: 100% of facility with no blind spots
  • Low-light Performance: IR illumination for 24/7 visibility
  • PTZ Capabilities: Strategic placement of pan-tilt-zoom cameras

Monitoring & Retention

  • Monitoring: 24/7 live security personnel monitoring
  • Storage: 90-day standard footage retention
  • Access Control: Role-based access to recorded footage
  • Analytics: Motion detection, object tracking, anomaly detection
  • Encryption: All stored footage is encrypted

For detailed information about CCTV data handling, retention periods, and access procedures, please refer to our Privacy Policy.

Remote Hands & Operational Procedures

Remote Hands Scope

Our included remote hands service covers a comprehensive range of tasks:

Visual Inspections

  • LED/display status verification
  • Physical condition assessment
  • Cable connection confirmation
  • Environmental condition checks

Basic Operations

  • Power cycling equipment
  • Button/switch operations
  • Basic configuration via console
  • Reseating components

Equipment Handling

  • Package receiving and unpacking
  • Inventory verification
  • Basic equipment mounting
  • Securing equipment for shipping

Cabling Tasks

  • Cable installation and labeling
  • Patch cord connections
  • Basic cable organization
  • Visual cable tracing

Service Level Agreements

Our remote hands service operates under clear SLA commitments:

Priority Response Time Resolution Target Coverage
P1 - Critical 15 minutes 2 hours 24/7/365
P2 - High 1 hour 4 hours 24/7/365
P3 - Normal 4 hours 8 hours Business hours
P4 - Low 8 hours 24 hours Business hours
Technician performing remote hands service on server equipment

Equipment Deliveries & Client Meetings

Our facility includes comprehensive support for equipment logistics:

  • Receiving Dock: Dedicated loading area with freight elevator
  • Package Processing: Inventory verification and secure storage
  • Delivery Notification: Immediate alert upon equipment arrival
  • Meeting Rooms: Private spaces for equipment handover or team work
  • Scheduling: 24-hour advance booking for equipment deliveries
  • Transport: Secure internal transport to your rack/cage location

Note: For equipment deliveries, please schedule at least 24 hours in advance through our customer portal or by contacting our operations team.

Monitoring, Alerting & Management

Monitoring station with multiple displays showing system status

Environmental Telemetry

Our comprehensive environmental monitoring system tracks critical facility metrics:

  • Temperature Monitoring: Multiple sensors per aisle with vertical profiling
  • Humidity Tracking: Relative humidity sensors throughout facility
  • Airflow Analysis: Pressure differential sensors for containment integrity
  • Leak Detection: Underfloor water detection cables
  • Air Quality: Particulate monitoring and fire detection

Power Monitoring

Extensive power metrics are collected and analyzed at multiple levels:

  • Facility Level: UPS load, generator status, transfer switch position
  • PDU Level: Circuit load percentage, current draw, power factor
  • Outlet Level: Individual outlet consumption (with switched PDUs)
  • Trending: Historical usage patterns and capacity planning
  • Efficiency Metrics: PUE calculation and optimization tracking

Network Monitoring

Basic network infrastructure monitoring includes:

  • Connectivity: Uptime monitoring of core network infrastructure
  • Utilization: Bandwidth usage tracking on shared infrastructure
  • Security: DDoS detection and anomaly identification
  • Cross-connects: Status monitoring of physical layer connections

Notification Channels

Alerts and notifications are delivered through multiple channels:

  • Email: Detailed alert notifications with actionable information
  • SMS: Critical alerts sent via text message
  • Phone: Automated calls for severe issues requiring immediate action
  • Customer Portal: Real-time status dashboard and alert history
  • Mobile App: Push notifications and status updates
  • Ticketing System: Automatic ticket creation for tracked issues

Compliance & Certifications

Operational Compliance

Our facility operations adhere to Latvian and European regulations governing data centers and information security:

Data Protection & Privacy

  • GDPR Compliance: Full adherence to EU data protection regulations
  • Latvian Data Protection Law: Compliance with local data protection requirements
  • Privacy Controls: Strict access controls for personal data
  • Data Processing: Transparent handling of all personal information
  • Subject Rights: Procedures to support data subject access requests

Facility & Safety Standards

  • Building Codes: Compliance with Latvian construction regulations
  • Fire Safety: Advanced fire detection and suppression systems
  • Electrical Safety: Regular testing and certification of electrical systems
  • Occupational Safety: Adherence to workplace safety requirements
  • Environmental Regulations: Compliance with local environmental laws

While specific certifications are continuously being updated and expanded, our facility currently operates in accordance with industry best practices and all applicable Latvian laws for data centers and colocation services. Our operations team can provide the most current compliance information for your specific regulatory requirements.

For clients with specific compliance needs, we offer documentation and access for third-party audits to verify our controls and procedures meet your regulatory requirements.